Arida Clean 600 Air Purifier with aerOHeal®
To avoid damage to the air purifier, health or other property, it is important that you follow these safety instructions at all times.
All repairs to the air purifier must only be carried out by the dealer or their recommended repairer.
- Do not touch the plug with wet hands. This may cause an electric shock.
- Do not use with a damaged power cord or plug. Do not twist the cord during use. Using a damaged cord may cause electric shock, short circuit or fire. Avoid cutting, bending, twisting or pulling the cord, or placing stress on the cord or plug. A damaged plug or cord must be replaced by a qualified electrician or service person.
- Do not disassemble or modify. This may cause electric shock, malfunction or fire.
- Use only 220-230V voltage. Exceeding the amperage may cause overheating and thus pose a fire hazard.
- Always unplug the power cord before maintenance. The air purifier may start unexpectedly, which could result in a risk of electric shock or other accident.
- Make sure the plug is properly inserted into the outlet. A loose plug or outlet may cause electric shock, overheating, or fire.
- Clean the plug regularly. Accumulation of dust and moisture on the plug can damage the insulation and thus cause fire or accident. Unplug the plug regularly and wipe it with a dry cloth. Remember to unplug the plug if the air purifier will not be used for a long period of time.
- Do not place objects in or around the air inlet and outlet. Especially curtains, blankets or blocking objects. This may damage internal components and cause electric shock or malfunction.
- Never clean the air purifier with solvents, such as gasoline, thinner, or insecticide. This may cause the air purifier to break, cause damage, short circuit, electric shock, or fire.
- Do not use the air purifier in areas with grease particles. Such as in the kitchen, as this may shorten the life of the filter. The air purifier should not be used for ventilation or extraction.
- Do not use the air purifier indoors with gas or other airborne pesticides. Chemical residues may accumulate inside the machine and be released from the exhaust, which may be harmful to health. After using in rooms with pesticides, make sure the room is thoroughly ventilated before using the air purifier. Never pull on the cord, only on the plug. Pulling on the cord may cause a short circuit, damage the cord, or cause a fire or electric shock.
- Avoid use in high temperature, humidity or wet areas, e.g. in the bathroom. The air purifier may absorb moisture, which may cause an electric shock or fire hazard.
- Never expose the air purifier to water. Use of damp or wet Air Purifier may cause electric shock or fire due to short circuiting of components.
- Do not add volatile or flammable materials to the machine. Always keep the air purifier away from fire and fire hazards!
Immediately unplug the appliance from the socket if you experience:
- The control panel does not work.
- A fuse or safety switch has blown.
- The power cord or power plug is abnormally hot.
- The air purifier produces a burning smell, abnormal noise, or vibration.
- Other abnormal conditions or errors.
⚠️ Warning!
Product overview

- Air outlet
- Air quality sensor
- Photoresistor/light sensor for automatic dimming
- Air intake

- Front cover
- Pre-filter
- HEPA filter
- Activated carbon filter
- Photocatalytic filter
- UV-C light
Control panel

- WiFi indicator (blinks when searching for WiFi, stays on when WiFi is connected)
- Filter replacement indicator
- ON/OFF button
- Fan speed
- UV light
- Ionization
- Child lock (hold for 3 seconds)
- Hours
- Reset filter indicator (hold for 5 seconds)
The air purifier is equipped with an air quality indicator, the diode on top of the control panel. This gives an indication of how clean the air measured in the room is.
| Indicator color | Values of PM2.5 | Air quality |
| Blue | 0 – 50 | Perfect |
| Green | 50 – 100 | Abrupt |
| Purple | 100 – 150 | Normal |
| Red | 150 – | Bad |
Filter replacement reminder
Based on the actual use of the filter, the machine automatically calculates the expiration time of the filter. After the filter expires, the filter replacement indicator flashes to remind you to replace the filter. Always turn off the air purifier and unplug it from the power outlet before replacing the air filters.
Air purifier placement

To ensure good air circulation in the room, there must be at least 50 cm of space at the back and front, and at least 10 cm of space to the sides.
Please keep a distance of 1 meter from TV, radio, etc.
Do not plug the air purifier into the same outlet as a TV, radio, or other electrical device. This may cause screen flickering and noise on other electronic devices.
- Prolonged placement in the same place can dirty the walls.
- To ensure that the machine has sufficient air circulation and achieves maximum efficiency, do not block the air outlet or air intake.
⚠️ Before use
Get started
When using this air purifier for the first time, it is important that the filters are installed correctly according to the instructions below. Remove all packaging and place the air purifier on a dry, stable and horizontal surface.
1.
Pull off the filter covers on both sides.
The front cover is attached with magnets and sits in a separate groove. Therefore, hold the center of both front covers and gently pull the front covers towards you.

2.
Remove all air filters

3.
Remove all packaging from the filters

4.
Put the filters back in the correct order.

5.
Replace the front covers and make sure they are in the slot. The air purifier is now ready for use.
Be careful when replacing the front covers on the machine. The magnets on the front cover should align with the magnets on the air purifier. The air purifier has grooves that the front cover should fit into to properly fit the air purifier.

Connecting to WiFi
The Arida Clean 600 has WiFi and can therefore be controlled remotely from a mobile phone or tablet. To connect the air purifier to WiFi and control it via your mobile phone, use the Smart Life app .
✅ Remote control – Control the air purifier from anywhere via your mobile phone.
✅ Automation – Set up schedules for automatic operation, like turning on the air purifier before you get home.
✅ Voice Control – Integration with Google Assistant and Amazon Alexa allows you to control the air purifier with your voice.
✅ Real-time data – See air quality in real time and get alerts.
✅ Multiple Devices – Control multiple smart devices in your home from one app.
✅ Shared Access – Give family members access to control the air purifier via their own accounts.
Click here to download Smart Life from the App Store or click here to download Smart Life from Google Play .

1. Download Smart Life from the App Store / Google Play and log in.

2. Turn on the air purifier and hold the fan speed button for 5 seconds until the WiFi symbol starts flashing.
Open Smart Life, press "+" and select "Small Home Appliances" -> "Air Purifier".

3. Enter the WiFi password and click "Next".

4. Complete the connection and press "Done". You have now connected the air purifier to WiFi and can control it remotely.
Air filtration with aerOHeal® purification system
Arida Clean 600 comes with the aerOHeal® purification system, an advanced and precise six-stage air filtration that ensures effective and safe air purification.

- Pre-filter
- HEPA filter
- Activated carbon filter
- Photocatalytic filter
- Ionization
- UV sterilization
Pre-filter
Washable fine mesh filter that effectively blocks fibrous particulate matter larger than 2.5 mm. This filter has a filtration efficiency of >99.9% and does not normally need to be replaced.
The pre-filter prevents larger particles such as animal hair, dander and coarse dust, etc. This extends the life of the other filters.
HEPA filter
High-efficiency composite filter that removes particles as small as 0.3 microns from the air stream. This filter has a filtration rate of 99.9%, which complies with European and international standards. The HEPA filter helps reduce the spread of allergens, bacteria, pollen, smog and viruses in the air stream.
Using activated carbon and precious metals as the filtration medium, it removes benzene, odors and other toxic substances in the air. The filter also helps eliminate secondary pollution that may occur through thermal desorption of harmful particles.
In addition, it removes volatile organic compounds such as secondhand smoke and other polluting gases, significantly improving air quality.
Activated carbon filter
The activated carbon filter removes volatile organic compounds (VOCs), including secondhand smoke and various types of polluting gases . This contributes to cleaner and fresher indoor air by absorbing harmful chemicals and unwanted odors.
Photocatalytic filter
Using Nano TiO₂ as the representative material, it has photocatalytic function , and under the influence of UV light, it will have a strong catalytic decomposition .
Effectively degrades formaldehyde, toluene, xylene, ammonia, TVOC and other pollutants .
Ionization
Produces large amounts of negative ions , physical adsorption, which effectively eliminates odors . Very beneficial in rooms with classic odors, e.g. basements, boats and storage rooms with low air circulation.
UV light
UV-C light that effectively kills a variety of common bacteria and viruses , and inhibits the production of bacteria and viruses.
The cold cathode UV lamp has a trigger voltage of only 500V and produces no ozone , making it safe to use.
Maintenance
⚠️ Before you maintain
⚠️ Do not immerse the air purifier or any components in water or other liquid unless specified in the cleaning procedures.
⚠️ Do not use corrosive or flammable gases (e.g. bleach or alcohol) to clean any part of the product.
⚠️ Only the pre-filter can be cleaned with water, the other filters must be replaced according to the maintenance interval.
Cleaning the surface
Regularly clean the central and lateral parts to avoid dust accumulation.
1️⃣ Use a soft, dry cloth to wipe away dust.
2️⃣ Use a soft, dry cloth to clean the air inlet and outlet .
Cleaning the air quality sensor
Clean the air quality sensor every two months to ensure the air purifier is working optimally. If used in a dusty environment , it should be cleaned more frequently.
When the humidity around the air purifier is very high, the air quality indicator may form condensation and therefore show poor air quality.
In this case, you need to clean the air quality sensor or use a manual fan setting to draw fresh air through the air purifier and thus dry the sensor.

3. Remove the front cover and air quality sensor cover

2. Clean carefully with a soft brush

3. Wipe with a dry cotton swab
Cleaning the pre-filter
⚠️ Clean the pre-filter regularly
⚠️ To achieve the best possible performance, you must clean and maintain the pre-filter every two months (approx. 480 hours ) from the first use.
⚠️ Use a low-power vacuum cleaner to avoid damaging the filter.
The cleaning interval is calculated based on an operating time of 8 hours per day, 7 days per week. This is considered normal household conditions. In case of heavier use, the pre-filter must be cleaned more frequently.
Filter replacement indicator reference time
When the machine's operating time reaches 3600 hours , the filter replacement indicator will start flashing.
Calculation of operating time per fan speed:
🔹 First fan speed: Total 0.25 seconds per second
🔹 Second fan speed: Total 0.5 seconds per second
🔹 Third fan speed: Total 1 second per second
🔹 Fourth fan speed: Total 2 seconds per second
Maintenance tips
💡 To safeguard your air purifier, your health, and the health of your family, it is important that the air filters are cleaned and replaced on time.
💡 After the filter is opened, its lifespan is shortened. It is recommended to replace air filters every 6 months for normal use, or every 12 months for less use.
💡 The air filters are fresh products and must be used for a maximum of 12 months before being replaced, regardless of operating time.
💡 The photocatalyst should be replaced every 3 years .
💡 After 1000 hours of UV light use , the sterilization efficiency is reduced to 70% , but it does not affect the effectiveness of removing volatile organic compounds such as formaldehyde and TVOC .
💡 If the air purifier is not going to be used for a while, it is important that the plug is unplugged, that the inside is thoroughly dried of moisture and that the machine is stored in an upright position in a dry and well-ventilated place.
Troubleshooting
If you experience errors or deficiencies that are not mentioned in this user manual, it is important that you contact the point of sale or importer.
| Problem | Possible causes | Solution |
| The air purifier does not turn on. | The front cover is not properly installed. | Remove the front cover and reinstall it. |
| The air purifier is not receiving power. | Unplug the power plug and plug it back in. | |
| The plug or cord is damaged. | Contact the importer, a dealer or an authorized electrician. | |
| The fan is not working. | The air purifier is not turned on. | Connect the plug to the power supply and turn the air purifier back on. |
| The dynamo is broken. | Contact the importer or a dealer. | |
| The air purifier is on an uneven surface. | Move the air purifier to a flat and stable surface. | |
| Loose objects in the air purifier. | Try to locate the object and get it out. If not, the air cleaner will need to be opened up to be removed and checked for other faults. | |
| The engine is loose. | Contact the importer or a dealer. | |
| The packaging around the filters has not been removed. | Remove the plastic packaging from all filters before use. | |
| The pre-filter is dirty. | Clean the pre-filter. | |
| The remaining filters are clogged. | Replace all air filters with new air filters. | |
| Air inlet or outlet is blocked. | Ensure there is at least 50 cm of clearance on both sides of the air intake and at least 10 cm behind the air purifier. Remove any carpets, curtains and other objects that may block the airflow. | |
| Poor performance or suboptimal air purification | The packaging around the filters has not been removed. | Remove the plastic packaging from all filters before use. |
| There is not enough space around the air purifier. | Ensure there is at least 50 cm of clearance on both sides of the air intake and at least 10 cm behind the air purifier. Remove any carpets, curtains and other objects that may block the airflow. | |
| The filters are missing or inserted in the wrong order. | Make sure all filters are installed in the correct order. | |
| The area in which the air purifier is located is larger than recommended. | Make sure the air purifier is used in a suitable room according to the specifications. |
Warranty